A sewer backup in a Vancouver basement is one of the most expensive and disruptive things that can happen to a house. Waste water comes up through the basement floor drain, the basement toilet or the basement shower, floods the lowest level, and leaves behind a cleanup that costs tens of thousands of dollars. Insurance may cover some of it, if the policy includes sewer backup coverage. It may not cover the rest.
A backwater valve is the device that stops this from happening. This post explains what a backwater valve is, when the BC Plumbing Code requires one, where it goes in a Vancouver home, and how to keep it working over time.
Because vancouver.ca returns errors to automated requests, specific Vancouver By-law requirements below are based on the City's archived pages, the BC Plumbing Code and common plumbing practice. Confirm current rules with the City of Vancouver or your plumbing contractor before the work begins.
A backwater valve is a one-way valve installed in the building's main drain line. Inside the valve body is a flap or a flapper that lets waste water flow in one direction, out of the house toward the city sewer, but closes when water tries to flow in the opposite direction.
The valve is a mechanical device with no power, no sensors and no controls. It works by the pressure of the water itself. When waste water flows out of the house, the flap hinges open and the water passes. When city sewer water flows back toward the house, the flap closes against a seal and blocks the flow.
The valve body has an access cover with a clean-out, which is used to inspect the flap and clean out any debris. The cover is usually at or near the floor level of the basement so it can be reached.
Vancouver's older neighbourhoods have combined sewers, which carry both storm water and sanitary waste in the same pipe. During a heavy rain event, the combined sewer can be overloaded. The water level in the sewer rises above the elevation of basement fixtures, and the water flows backwards into any house that is connected without a backwater valve.
The City has been separating combined sewers into dedicated storm and sanitary lines for decades. Many streets now have separated systems. But in older neighbourhoods, the combined sewer is still in place, and until the City completes the separation, the risk of a surcharge during a heavy rain event remains.
In addition to heavy rain, a blockage in the city sewer line downstream of the house can cause the same backup situation. A tree root growing into the city main, a grease clog, or a construction error can block the flow. Water from upstream houses continues to drain into the blocked pipe, which then surcharges back toward every house above the blockage.
A backwater valve is the device that protects a Vancouver basement from both of these situations.
The BC Plumbing Code requires a backwater valve wherever a fixture is located below the elevation of the next upstream manhole in the city sewer. The next upstream manhole is the manhole in the city sewer line that is closer to the source of the water (further up the hill). The elevation of that manhole is the maximum level that water could reach during a severe surcharge event, after which it would overflow onto the street.
In practice, the next upstream manhole is above the elevation of a typical basement floor in Vancouver. So a basement fixture (floor drain, toilet, shower, laundry) is below that elevation and is a candidate for backflow protection.
The Code offers two approaches:
- A backwater valve on the drain line that serves the fixtures below the critical elevation.
- A separate drain system for the basement fixtures, pumped up to a point above the critical elevation.
In most Vancouver homes, the first approach is used: a backwater valve on the drain line for the basement fixtures, usually located where the drain is about to leave the house.
The location of a backwater valve is a design and installation decision made by the plumbing contractor based on the layout of the drain system, the location of the fixtures, and the accessibility requirements.
In a typical new Vancouver home, the valve is installed in the main drain line between the point where the basement fixtures connect and the point where the drain leaves the house to connect to the city sewer. This placement protects the basement fixtures while leaving the upper floor fixtures connected to the sewer without a valve, so they drain normally even if the valve closes during a surcharge.
The valve needs:
- Access. An access hatch in the floor or an access cover on the valve body, large enough to reach the flap for inspection and cleaning.
- Clearance. Enough space around the valve to work on it without disassembling the drain.
- Correct orientation. The valve must be installed in the direction of flow, with the inlet toward the house and the outlet toward the city sewer. Installing it backwards is a common error that makes the valve non-functional.
- Level installation. The valve must be installed level so that the flap hangs correctly. A sloped installation can prevent the flap from sealing.
For a renovation where the basement drain is already in place, the valve is often installed in a pit under the basement slab, with an access hatch flush with the floor. A section of the slab is cut out, the valve is installed, the slab is patched, and the access cover is sealed into the patch.
For a new build, the valve is installed as part of the under-slab drain system before the slab is poured. The access hatch is cast into the slab.
A backwater valve protects the fixtures downstream of the valve. For a typical installation where the valve is before the drain leaves the house, every basement fixture is downstream of the valve in the sense that waste water from the fixture passes through the valve on its way out. These fixtures are protected from backflow because the valve closes before the sewer backup reaches them.
Upper floor fixtures are typically connected to the sewer by a drain line that joins the main after the backwater valve. These fixtures are not downstream of the valve, so they are not protected. But because they are above the critical elevation, they do not need protection.
One situation that requires attention: if the valve closes during a sewer backup, the upper floor fixtures can still drain, but only until the drain line between them and the valve fills up. If the backup lasts long enough, the upper floor fixtures can back up into the same situation. In practice, surcharge events are short enough that this is rare, but it is not impossible.
A backwater valve is a mechanical device, and it needs maintenance. Over time, debris can accumulate in the valve body: hair, grease, bits of paper, food particles. Some debris can lodge in the hinge of the flap, or against the seal, and prevent the flap from closing fully when water tries to flow backwards.
Routine maintenance:
- Annual inspection and cleaning. A plumber or the homeowner opens the access hatch and inspects the valve. Any debris is removed. The flap is checked to confirm it moves freely and seats correctly.
- After a known event. After a heavy rain event, or after any sign of a sewer problem, the valve should be inspected to confirm it is still working.
- Before an insurance renewal. Some insurance policies with sewer backup coverage require that the valve be maintained. Keeping a record of annual inspections is useful if a claim ever arises.
The homeowner can do a visual inspection. The plumber should do the full cleaning, because the valve body may need to be partially disassembled and the flap lifted to clean the seat.
Most home insurance policies in BC include sewer backup coverage as an optional endorsement, not as part of the base policy. If sewer backup is a risk for the property (and it is for most Vancouver homes), add this endorsement to the policy.
Some insurance companies require a backwater valve as a condition of the endorsement, and some reduce the deductible if a valve is installed. Keep a record of the valve installation (the permit, the invoice) and of the annual maintenance.
If the house does not have a backwater valve, the insurance company may decline the endorsement, or offer it only at a high deductible.
- Confirm that your home has a backwater valve. If you bought an older Vancouver home and you do not know, ask a plumber to inspect and confirm. If there is no valve, consider having one installed.
- Inspect the valve annually. Open the access hatch, look for debris, and check that the flap moves freely. Clean it or have a plumber clean it.
- Add sewer backup coverage to your insurance. Confirm with your insurance company what the conditions are for this coverage.
- Know where the valve is. If you ever have a sewer problem, the first check is the backwater valve.
For a new build or a multiplex, we design the backwater valve into the plumbing from the start. We work with the plumbing contractor to confirm the location, the access, and the maintenance clearance. We keep the valve where the homeowner can reach it.
For a renovation that touches the basement drain, we add a backwater valve if the home does not already have one. We arrange a Technical Safety BC gas permit (where gas work is also happening) and a City plumbing permit, so the work is inspected.
At handover, we show the homeowner where the valve is, how the access cover works, and what the annual inspection involves. We keep the valve installation record in the project file.
Tell us about your project today. Book a one-hour project consultation.
Related on this site: Crawl space vs full basement for a new Vancouver home · Secondary suite requirements in Metro Vancouver · Building through Vancouver's wet season